Categories
Articles

PNOZsigma PILZ PNOZ s5 C Safety Relays

The PNOZ s5 is part of Pilz’s PNOZsigma series, known for their safety-related functions in industrial applications. Its delay-on de-energisation feature makes it suitable for applications where controlled shutdown sequences or timed operations are critical.This type of functionality is commonly used in safety circuits, where it ensures that certain operations or shutdowns are delayed to allow for specific conditions or sequences to complete before the system is fully de-energized.

The output contacts will change their state (e.g., from closed to open) after the delay period has elapsed following de-energisation of the coil.Refers to the state when the control voltage to the relay coil is removed, causing it to deactivate. The relay operates with a delay timer mechanism that starts counting down once the relay coil is de-energized.

The PNOZ s5 timer relay is indeed a base unit that provides delay-on de-energisation functionality. http://www.pilz.com This means that when the relay coil is energized, the output contacts remain in their initial state (usually open) for a certain period after the coil is de-energized.

Categories
Articles

PILZ PSENslock 2 Safety Locking Devices | PT.Felcro Indonesia

Using tried and tested safety devices like PSENslock is crucial for ensuring the protection of personnel and machinery in industrial settings. http://www.pilz.com It’s important to maintain and periodically review the effectiveness of such safety measures to ensure continued reliability and safety compliance.

PSENslock is designed to meet the highest safety standards by combining safe position monitoring and process guarding features. This dual functionality likely ensures that both the position of machinery components and the overall process are monitored for safety, which is essential in high-risk industrial environments. Such devices are instrumental in preventing accidents and ensuring compliance with safety regulations. Safety solutions provider since 2011, We offer Pilz

Categories
Articles

PMCtendo DD – Servo amplifier from PILZ

The PMCtendo SZ synchronous motor from Pilz is designed specifically for on-board axes and installations where space is limited. It is known for its extremely smooth running characteristics, which is crucial in applications where precision and low vibration are important. Operates on synchronous motor principles, ensuring precise control and synchronization with the drive system. http://www.pilz.com

Suitable for installation in confined spaces, making it ideal for applications where space is limited or where a compact motor is necessary. Known for its extremely smooth running, which is beneficial for applications requiring low vibration and high precision. Typically used in on-board axes, which implies it can be integrated into machinery and equipment where mobility or compactness is a consideration. Safety solution provider since 2011

Pilz is known for its quality and reliability in automation technology, ensuring that the PMCtendo SZ meets rigorous standards for performance and durability. PMCtendo SZ synchronous motor combines compactness with smooth operation, catering to applications where both space constraints and high performance are critical factors.

Categories
Articles

PSENslock – Safety locking devices – Pilz

The PSENslock is a safety locking device commonly used in industrial settings to ensure the safety of machinery and equipment. It features electromagnetic guard locking, which means it uses an electromagnetic field to lock and unlock the guard. This ensures that the guard remains securely closed during operation, preventing access to hazardous areas.

The safety switch and actuator are integral components of the PSENslock system. The safety switch is typically installed on the guard, while the actuator is mounted on the machine frame. When the guard is closed, the actuator aligns with the safety switch, allowing the PSENslock to detect that the guard is properly closed and engage the electromagnetic lock. http://www.pilz.com

Categories
Articles

PNOZ m C0 – Modular Safety Relays

Some versions of the PNOZmulti 2 may support Pilz’s proprietary SafetyBUS p, a safety network protocol. SafetyBUS p enables the connection of multiple safety devices and facilitates communication between them, enhancing the overall safety of the system.

With the connectivity options mentioned earlier, users can remotely monitor the status of the safety system, receive alerts for any faults or alarms, and even perform troubleshooting procedures from a central location. http://pilz.com

Pilz may provide dedicated software for visualizing the safety-related data and diagnostics of the PNOZmulti 2 controller. This software allows users to monitor the safety system in real-time, view diagnostic information, configure parameters, and generate reports.

The PNOZmulti 2 may offer various connectivity options such as Ethernet, USB, or serial connections, allowing for communication with other devices such as PCs, HMI (Human-Machine Interface) panels, or PLCs (Programmable Logic Controllers). This connectivity enables remote monitoring, programming, and diagnostics.

The controller often comes equipped with diagnostic LEDs that provide visual indications of the controller’s status and any occurring faults. These LEDs typically display information such as power status, operational status, and fault codes.

Categories
Articles

PNOZsigma | PT. Felcro Indonesia

The PNOZsigma relays are compact safety relays in widths 22.5mm and 45mm. They are used for monitoring E-STOP, safety gates, light barriers, two-hand controls or ESPEs with safe PNP transistor outputs and contact EDM. The relays are jumper link programmable for either PNP or NPN signals. http://www.pilz.com

They must be connected to a remote RESET device such as a pushbutton station to initiate the reset enabling function. The remote reset can reset the contacts if the pushbutton is held closed for more than 0.5s and can reset both the contacts and the internal relays if the pushbutton is held closed for more than 3s.

The chapter “Technical Description” is the first of several chapters that provide technical details of the PNOZsigma relays. The chapter is an introduction to the PNOZsigma relay range and offers an overview of the product range and the functions that are common to all relays in the range, before giving the variable features of the individual relays in later chapters. Safety solution provider since 2011, We offer pilz safety relays pnozsigma http://www.pilz.com

Categories
Articles

The best pilz e-stop | PT.Felcro Indonesia

This guide is not specifically targeted to persons only using Pilz controllers, in fact, most of the information can be used as a generic guide to automation with PLCs. Any information on this PLC is applicable to the Sercos or Ethernet bus for all control systems using fieldbus operation. This guide will give you insight and experience on control system development and programming with equipment and scenarios typical of today’s industry. Violet’s website is not limited to just PLC programming, Electronics troubleshooting and wiring with virtual equipment is explained in great detail to get the best understanding possible of control system operation. Violet will also give you practice on some control systems and program scenarios with the virtual equipment to further increase understanding. All practice sessions are focused around the PSS 4000 and Sercos bus but in every scenario, it is possible to relate the information to other PLC controllers. Due to online changes on Sercos operation and setup, not all scenarios will have the exact step by step practice. This guide may be of use in control system courses at colleges or industry for further PLC understanding and programming practice. No matter whom you are, a control system engineer, electrical technician, or a student, this guide will give you valuable information and experience on PLCs. The best pilz automation

Any changes made in PLC programming can be tested offline, providing a means of simulation to see the effects at the IT level or anywhere in between without any physical changes to the plant floor devices. The programming changes can also be stored and forwarded to an offsite location for disaster recovery solutions. Note that with the ever-changing technology, Pilz network products support various protocols and have multi-protocol capabilities. This ensures that network integration can be achieved regardless of what generation the control device may be. The best pilz automation

Categories
Articles

The best pilz in indonesia

Safety relays monitor the faults in the interlock devices. The basic logic used is based on the conditions of the input and output wiring. Input wiring is the voltage that the safety relay will accept to energize the relay to switch the output contact. The output contact will turn the machine off using the interlock devices. Internal logic is represented in the truth table, which shows the relationship between the input and the output wiring. From the truth table, the next step is developing the functions and faults equations. These equations are very important to find the minimal sum of products, which later develop the ladder logic. The final considerations are to implement the functions equation into the ladder logic. The safety relay also must be user friendly to someone troubleshooting the system. A fault in the system can be determined through testing the machine and forcing the input wiring to simulate a fault condition. LED indicators are useful to show the system is functioning, off, and a fault in the system. The last consideration is the modification of the function block. If a function’s equation is changed, the ladder logic can also be changed using software and just download it to the safety relay. http://www.felcro.co.id

Safety relays are the logical development of electromechanical relays, during those applications where safety, availability, and their costs are the major concern. These relays have enabling contacts and mirror contacts in one or more linked pairs which change over when the relay is actuated. Safety relays are used for monitoring the dangerous outputs and provide superior failure mode analysis such as a light curtain to assure that it does not decrease harm. http://www.felcro.co.id

Categories
Articles

Automation App Award 2023

Our innovative Key-in-pocket maintenance safeguarding system, which guarantees protection against unintended machine restarts, won third place in the Automations Best Award 2023, in the “Best Solutions” category. Readers of the media concepts “messtec drives” and “inspect” voted in our favour.Also, our new “Safety Distance Calculator” browser tool was awarded second place in the Automation App Award. The decisive factor that led to this development was as follows: “We want to support our customers with competence and the best possible environment” – Tobias Ulmer, Product Manager responsible for safety light curtains. http://www.pilz.com
The tool enables the safety distance for safety light curtains to be calculated simply as well as safely. Users save a significant amount of time and can immediately identify the right safety light curtain for their plant. http://www.pilz.com

Categories
Articles

Supreme Multitasking

As part of a retrofit, the production furnace manufacturer Aksoylar Robotik pursued its aim of converting its roller hearth furnaces to the state of the art in terms of operability, monitoring and safety. With the burner management system that was installed previously it was not possible to network the control units of the individual furnaces. What’s more, status, process and diagnostic data could not be displayed consistently, as desired, nor could error messages be assigned and rectified quickly. With the safe small controller PNOZmulti 2, which has been adapted to the special needs of heat treatment furnaces, customers of Aksoylar Robotik can now safely monitor and simultaneously control multiple burners, plus the whole furnace, in one system. http://www.pilz.com

The roller hearth furnaces from Aksoylar are equipped with multiple burners and are used for the specific heat treatment of metals such as steel and aluminium. They are flexible and intended for use in a variety of industrial applications. With safe monitoring of individual burners and simultaneous control of the entire furnace via the burner solution – in other words via a single safety system – for Aksoylar Robotik, it was the solution of choice. Using the software function block on the small controller, which electronically emulates the extended functionality of an automatic burner control, specific burner applications can be configured easily. For example, typical requirements include the control of safety, ignition and exhaust valves or the monitoring of combustion air pressure, flame, ignition and much more. The result: safe operation of burners, stable processes and, above all, high-quality production results in the roller hearth furnace. http://www.pilz.com